Comparison of the performance of intraoral X-ray sensors using objective image quality assessment

DSpace Repository

Comparison of the performance of intraoral X-ray sensors using objective image quality assessment

Overview

Detailed record

dc.contributor.author Johansson, Curt sv
dc.contributor.author Nilsson, Mats sv
dc.contributor.author Hellén-Halme, Kristina en_US
dc.date.accessioned 2017-07-06T11:08:17Z
dc.date.available 2017-07-06T11:08:17Z
dc.date.issued 2016 en_US
dc.identifier.issn 2212-4403 en_US
dc.identifier.uri http://hdl.handle.net/2043/23046
dc.description.abstract Objectives. The main aim of this study was to evaluate the performance of 10 individual sensors of the same make, using objective measures of key image quality parameters. A further aim was to compare 8 brands of sensors. Study Design. Ten new sensors of 8 different models from 6 manufacturers (i.e., 80 sensors) were included in the study. All sensors were exposed in a standardized way using an X-ray tube voltage of 60 kVp and different exposure times. Sensor response, noise, low-contrast resolution, spatial resolution and uniformity were measured Results. Individual differences between sensors of the same brand were surprisingly large in some cases. There were clear differences in the characteristics of the different brands of sensors. The largest variations were found for individual sensor response for some of the brands studied. Also, noise level and low contrast resolution showed large variations between brands Conclusions. Sensors, even of the same brand, vary significantly in their quality. It is thus valuable to establish action levels for the acceptance of newly delivered sensors and to use objective image quality control for commissioning purposes and periodic checks to ensure high performance of individual digital sensors. en_US
dc.format.extent 9
dc.language.iso eng en_US
dc.publisher Elsevier en_US
dc.subject Dentistry, Oral Surgery & Medicine en_US
dc.subject.classification Medicine en_US
dc.title Comparison of the performance of intraoral X-ray sensors using objective image quality assessment en_US
dc.type Article, peer reviewed scientific en_US
dc.contributor.department Malmö University. Faculty of Odontology
dc.identifier.doi 10.1016/j.oooo.2016.01.016 en_US
dc.subject.srsc Research Subject Categories::ODONTOLOGY en_US
dc.relation.ispartofpublication Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology;5
dc.relation.ispartofpublicationvolume 121 en_US
dc.description.authorversion No en_US
dc.identifier.isiid 000375608100006
dc.identifier.pmid 27068317
dc.format.ePage e137
dc.format.sPage e129