Impact of peri-implant buccal bone thickness, implant fixture diameter, abutment and/or prosthetic reconstruction material on the accuracy of Cone Beam Computed Tomography to assess peri-implant buccal bone level: an in vitro study in pig jaw

DSpace Repository

Impact of peri-implant buccal bone thickness, implant fixture diameter, abutment and/or prosthetic reconstruction material on the accuracy of Cone Beam Computed Tomography to assess peri-implant buccal bone level: an in vitro study in pig jaw

Overview

Detailed record

dc.contributor.author Ahmad, Salman
dc.date.accessioned 2018-10-19T12:17:27Z
dc.date.available 2018-10-19T12:17:27Z
dc.date.issued 2018 en_US
dc.identifier.uri http://hdl.handle.net/2043/26517
dc.description.abstract Abstract Aim: To evaluate the impact of peri-implant buccal bone thickness, implant fixture diameter, abutment material (Titanium Ti, Zirconium Zr) and/or prosthetic reconstruction material (metal ceramic vs ceramic) on the accuracy of Cone Beam Computed Tomography (CBCT) to assess peri-implant buccal bone level. Materials and methods: Titanium implants were inserted into 36 blocks of pig mandible in a way to create variable buccal bone thicknesses groups, each group with 12 blocks; group 1 (0.5-1 mm), group 2 (>1-1.5 mm) and group 3 (>1.5-2 mm), half of each group received a dehiscence which was created of variable extent. Two groups regarding abutment-crown material; (Ti abutment with CoCr crown, Zr abutment with Zr crown) and implant diameter; (standard/narrow) were assessed. Dehiscences were measured on CBCT image using 2 programs (i-Dixel and Photoshop) and were compared to the gold standard. Results: Thin buccal bone thickness group (0.5-1 mm) had major impact on the accuracy of CBCT to correctly detect and measure the extent of a bony dehiscence. No differences were detected between standard or narrow diameter implant and between TiTi/CoCr combination and TiZr/Zr combination in regards to possibility of CBCT to detect and evaluate accurately the extent of a bony dehiscence. Conclusion: Thin peri-implant buccal bone (≤ 1 mm) has a negative effect on the accuracy of CBCT to assess peri-implant buccal bone level. The possibility to identify and to assess the extent of peri-implant buccal bone dehiscence in CBCT was hardly affected by using different abutments and crown materials and different implant diameters. en_US
dc.language.iso eng en_US
dc.publisher Malmö universitet/Odontologiska fakulteten sv-SE
dc.title Impact of peri-implant buccal bone thickness, implant fixture diameter, abutment and/or prosthetic reconstruction material on the accuracy of Cone Beam Computed Tomography to assess peri-implant buccal bone level: an in vitro study in pig jaw en_US
dc.type H2 en_US
dc.setspec.uppsok Medicine en_US
dc.contributor.examiner Truedsson, Anna
dc.contributor.supervisor Stavropoulos, Andreas
dc.contributor.supervisor Bertl, Kristina
dc.contributor.supervisor Hellen-Halme, Kristina
mahlocal.xprt.faculty2019 OD
mahlocal.xprt.institution2019 OD
mahlocal.xprt.program Master Program in Dental Science