The impact of a modified cutting flute implant design on osseointegration

DSpace Repository

The impact of a modified cutting flute implant design on osseointegration

Details

Files for download

Find Full text There are no files associated with this item..

Overview of item record
Publication Article, peer reviewed scientific
Title The impact of a modified cutting flute implant design on osseointegration
Author Jimbo, Ryo ; Tovar, N. ; Marin, C. ; Teixeira, H. S. ; Anchieta, R. B. ; Silveira, L. M. ; Janal, M. N. ; Shibli, J. A. ; Coelho, P. G.
Date 2014
English abstract
Information concerning the effects of the implant cutting flute design on initial stability and its influence on osseointegration in vivo is limited. This study evaluated the early effects of implants with a specific cutting flute design placed in the sheep mandible. Forty-eight dental implants with two different macrogeometries (24 with a specific cutting flute design Blossom group; 24 with a self-tapping design - DT group) were inserted into the mandibular bodies of six sheep; the maximum insertion torque was recorded. Samples were retrieved and processed for histomorphometric analysis after 3 and 6 weeks. The mean insertion torque was lower for Blossom implants (P < 0.001). No differences in histomorphometric results were observed between the groups. At 3 weeks, P = 0.58 for bone-to-implant contact (BIC) and P = 0.52 for bone area fraction occupied (BAFO); at 6 weeks, P = 0.55 for BIC and P = 0.45 for BAFO. While no histomorphometric differences were observed, ground sections showed different healing patterns between the implants, with better peri-implant bone organization around those with the specific cutting flute design (Blossom group). Implants with the modified cutting flute design had a significantly reduced insertion torque compared to the DT implants with a traditional cutting thread, and resulted in a different healing pattern.
DOI https://doi.org/10.1016/j.ijom.2014.01.016 (link to publisher's fulltext.)
Publisher Elsevier
Host/Issue International Journal of Oral and Maxillofacial Surgery;7
Volume 43
ISSN 0901-5027
Pages 6
Page 883-888
Language eng (iso)
Subject implants
cutting flute design
macro-geometry
thread design
insertion torque
histomorphometry
primary stability
secondary stability
osseointegration
Medicine
Research Subject Categories::ODONTOLOGY